Skip to product information
1 of 1

Asisales

Flow Table - ASI-520

Flow Table - ASI-520

This is used for determining the work ability of building limes.

Specifications: The Flow table consists of a 30cm. dia. ground and polished steel plate with three inscribed annular circles.7, 11 and 19cm. dia. The table top is arranged for a free fall of 12.5mm by a cam action. Supplied complete with one brasconical mould, 65mm I.D. at base and 40mm I.D. at top, height of the mould 90mm.

Read more

View full details
Standard Title Scope Key Test / Procedure
IS: 6932 (Part VIII) Method of Tests for Building Limes – Part 8: Determination of Unsoundness Specifies the method to determine the unsoundness of building lime, which affects its stability in construction.
  • Apparatus: Le Chatelier Mould
  • Preparation of lime paste
  • Filling the mould and covering with a glass plate
  • Initial water bath immersion at 50°C for 30 minutes
  • Boiling for 3 hours and cooling
  • Measurement of needle separation
  • Result: Expansion should not exceed 10 mm for sound lime