Specification |
Control mode | A8 Embedded platform |
Data storage | ≥4GB |
Operation mode | Key + touch screen |
Sentinel magnify(time) | 1,2,5,10,20,50,100 adjustable |
A/D resolution(bit) | True 24 bits A/D |
Sampling time intervals(μS) | 1~64000 adjustable |
Max length of sampling | 4096 |
Trigger | Signal trigger |
Noise voltage of the system(mV) | ≤1 |
Dynamic range(dB) | ≥184 |
Amplifier frequency range(Hz) | 10~10K |
Time value error | 4096 |
Time resolving power(us) | ≤10% |
Gain error(dB) | ≤1% |
Work time(h) | >8 |
Number of channels | 2 |
Interference between the channels | ≤1% |
Transducer/probe sensitivity (Acceleration mode) (mv/g) | ≥100 |
Frequency range of Probe (Acceleration probe) (Hz) | 0.5~9000 |
Port | Double USB |
Wi-fi | Yes |
Power |
Internal: Built-in battery |
External: 220VAC/DC |
Operational environment |
Temperature (℃): -10~+50 |
Humidity (RH): <90% |