+91-11-25920433

+91-11-41428065


16 2

Air Conditioning Test Rig

Aim :
 
This Laboratory scale working model housed on a M.S. Square tube frame further mounted on a wheels (CI) with instrumentation panel is used i) To study the Vapour Compression Cycle ii) To calculate co-efficient to performance (COP) iii) To evaluate tonnage capacity iv) To study humidification and dehumidification.
 

Detailed Description

 
01. Hermitically Sealed Compressor
Capacity : 1.0 Ton
02. Air Cooled Condenser
Capacity : 1.0 Ton
03. Condenser Cooling Fan
Capacity : 1/10 HP
04. Rota Meter (Refrigerant R 22) 1 No
05. Hand Shut Off Valves
Size : 3/8 & 1/4”
06. Filter Drier DM 50 (3/8 )” Type
07. Energy Meters 2 NO.
08. Thermostat 1 NO
09. Pressure/ Compound Gauges
1 Nos Each. Range : 0 to 300 psi/-30” Hg to + 150 Psi
10. Measuring Instruments
a) Digital Temperature Indicator Ambient to199.9deg. c.
11. Finned Heater 1 NO.
12. Electronic Dimmer 1 NO
13. Hp/Lpcutout 1 NO.
14. Air Conditioning Duct 1 SET
15. Steam Generator 1 SET
16. Anemometer 1 NO.
Optional : At Extra Cost Line Voltage Corrector
Capacity : 4KVA
Output : 230V+/- 10%